밸브   |   에이지밸브 AGE VALVE



공압 2차 압력 감압 밸브
2nd PRESSURE REDUCING VALVE
AGE313-SERIES.png
Description

2차 압력 감압 밸브는 제어안전성, 정밀성이 뛰어나고 구경선정이 용이합니다. 특정 HP 버터플라이 밸브(Anti-Blowout형)를 사용하는 경우 대구경 설비에 경제성이 큽니다.


​​​​​
PRODUCT INFORMATION   > AGE313 SERIES


SPECIFICATION
Valve Body
Globe
HP Butterfly
​Size
Globe: 15A(1/2″)~300A(12″)
BFV: 25A~1200A(1″~48″)
​Actuator
Globe: Diaphragm
BFV: Rack & pinion gear, Scotch yoke
Air supply
Globe: 2~3kg/㎠
BFV: 4~7kg/㎠
Accessories
Air set, controller
TECHNICAL DATA
​Services
​​Pressure reducing for water, oil, gas & steam On off
Action
Closing by increasing downstream pressure
​Hysteresis
​0.02×set pressure (kg/㎠)
INSTALLATION AND HOOK-UP


2nd-PRV-installation-B.png
HP BUTTERFLY VALVE
2nd-PRV-installation-G.png
GLOBE VALVE
Examples of Installation
① Shut off valve
⑤ Impulse tubing
⑨ Condensate pot
⑬ Control valve
② Control valve
⑥ Pressure indicator
⑩ Safety valve
⑭ Controller(AGE311O)
③ Controller(AGE313C)
⑦ Syphon tube
⑪ Controller(2)
⑮ dP indicator
④ Air supply
⑧ Block valve
⑫ Solenoid valve
⑯ Orifice flange
​​​​​​​​단순압력 조절 밸브
설치2nd_단순압력조절밸브.png1,2차 압력, 유량의 변동에 영향을 받지 않으며 컨트롤러의 압력을 2차측에서 감지합니다. 
고온의 서비스에서는 콘덴세이트 포트 또는 사이폰 튜브를 사용합니다.








​​​​



증발기 압력 조절(간접 로컬 온도 컨트롤)
설치2nd_증발기압력조절밸브.png증발기에 필요한 스팀 유량을 제어합니다.
컨트롤러에 입력되는 압력은 콘덴세이트 증발기의 상부에서 도압됩니다.











압력 조절 & PWM PID 로컬 온도 제어(제조사 패키지 공급) 
설치2nd_압력조절pwm밸브.png
압력제어기능과 함께 펄스 폭 PID 제어기능을 통해 온도를 제어합니다(복합제어기능).
TIC의 온도센싱입력은 열교환기에 연결되고 컨트롤러 입력은 밸브의 2차측과 연결됩니다.